VERIFIKASI PARAMETER PENGUJIAN SURFAKTAN ANIONIK DALAM AIR LIMBAH DENGAN METODE MBAS MENGGUNAKAN SPEKTROFOTOMETER UV-VIS

  • Stefanie Victoria Jurusan Kimia, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Mulawarman
  • Saibun Sitorus Jurusan Kimia, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Mulawarman
  • Aman Sentosa Panggabean Jurusan Kimia, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Mulawarman

Abstract

Determination of the parameters verification of anionic surfactants in waste water samples based on the MBAS (Methylene Blue Active Substances) method using a UV-Vis spectrophotometer has been done. Verification of  the measurement parameters refer to SNI 06-6989.51- 2005. The measurement results of several verification parameters is good showed that the linearity of the measurement indicated by the correlation coefficient value of 0.9909. The detection limit and quantitation limit values ​​obtained were 0.3622 mg/L and 1.2072 mg/L respectively. The precision value with %RSD was 2.5415%, and the %RPD value was 3.0686%. It is stated that this method can be used for the analysis of anionik surfactants in laundry wastewater and can be applied as a routine test at PT. Global Environment Laboratory.

Keyword
Anionik surfactant, UV-Vis Spectrophotometer, Waste water, Verification method

Downloads

Download data is not yet available.

References

[1] Khaliq, A. (2015). Analisis Sistem Pengolahan
Air Limbah Pada Kelurahan Kelayan Luar
Kawasan IPAL Pekapuran Raya PD PAL Kota
Banjarmasin. Jurnal Poros Teknik. 7(1), 1-53.
[2] Hendra, Barlian, E., Razak, A. dan Sanjaya, H.
(2016). Photo-Degradation Of Surfactant
Compounds Using UV Rays With Addition Of
TiO2 Catalysts In Laundry Waste. Padang :
Universitas Negeri Padang.
[3] Ulya, R. N., Yusuf, B., dan Panggabean, A. S.
(2016). Optimasi Kinerja Analitik Pada
Penentuan Surfaktan Anionik Dalam Sampel Air
Alam Menggunakan Metode MBAS (Methyl
Blue Active Subtance). Jurnal Atomik. 1 (1),
Hal. 36-41.
[4] Pratiwi, E. dan Prasetya, A. T. (2019). Optimasi
Metode Analisis Kadar Surfaktan Anion
Menggunakan Methylen Blue Active Subtances
dengan Spektrofotometer Ultraviolet Visible.
Indonesian Journal of Chemical Science. 9(2),
Hal. 125-130.
[5] Rifai, K. R. dan Anissa. (2019). Verifikasi
Metode Pengujian Coliform dalam Sampel Air
Mineral. Jurnal Teknologi Proses dan Inovasi
Industri. 4(2), Hal. 45-51.
[6] Riyanto. (2014). Validasi & Verifikasi Metode
Uji Sesuai Dengan ISO/IEC 17025 Laboratory
Pengujian dan Kalibrasi. Yogyakarta:
Deepublish.
[7] Panggabean, A.S., Pasaribu, S.P. and Kristiana,
F. (2018). The Utilization Of Nitrogen Gas as a
Carrier Gas in the Determination of Hg Ions
Using Cold Vapour-Atomic Absorption
Spectrophotometer (CV-AAS), Indo. J. of Chem.
18(2), pp. 279-285.
[8] Miller, J.N. and Miller J.C. (2005). Statistics
and Chemometrics for Analytical Chemistry.
5thEdition. Pearson Education Limited, England.
[9] Aji, A.W. (2020). Analisis Surfaktan Anionik
Dengan Metode Spektrofotometri Menggunakan
Metilen Biru Pada Sampel Limbah Inlet dan
Outlet Di Laboratorium Kesehatan Daerah DKI
Jakarta (Skripsi). Yogyakarta : Universitas
Islam Indonesia.
[10] Napitupulu, R.M., Julia, D., dan Panggabean,
A.S. (2019). Validasi Metode Penentuan Mn
Dalam Oli Lubrikan Dengan Metode
Pengenceran Langsung Menggunakan
Spektrofotometer Serapan Atom, Indonesian
Journal of Chemical Research, 6(2), Hal. 94-
100.
[11] Panggabean, A.S., Wirdhaningsih, and Pasaribu,
S.P. (2020). Preconcentration of Ion Ni (II)
using Ca-Alginate Modified Resin with
Dimethylglyoxime as a Filler Material of
Column, Jurnal Kimia Valensi 6(1), pp. 40-46.
[12] Hadi, A. dan Asiah. (2020). Verifikasi Metode
Pengujian Air dan Air Limbah Mendukung
Penerapan ISO IEC 17025:2017. IPB Press :
Bogor.
Published
2022-08-30
How to Cite
VICTORIA, Stefanie; SITORUS, Saibun; PANGGABEAN, Aman Sentosa. VERIFIKASI PARAMETER PENGUJIAN SURFAKTAN ANIONIK DALAM AIR LIMBAH DENGAN METODE MBAS MENGGUNAKAN SPEKTROFOTOMETER UV-VIS. JURNAL ATOMIK, [S.l.], v. 7, n. 2, p. 15-19, aug. 2022. ISSN 2549-0052. Available at: <http://jurnal.kimia.fmipa.unmul.ac.id/index.php/JA/article/view/1113>. Date accessed: 26 apr. 2024.
Section
Artikel