ANALISIS TERMODINAMIKA SISTEM HIBRIDA PV/T BERDASARKAN MODEL TERMAL

  • Dadan Hamdani Jurusan Fisika Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Mulawarman
  • Yuki N Nasution Jurusan Fisika Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Mulawarman

Abstract

In this paper, the analysis of PV/T system with air collector have been done as an attempt to investigate the system performances based on energy and exergy analysis using thermodynamics (thermal) analysis. The experimental data for a typical day of July, 9 th 2012 for Bontang City, East Kalimantan are used for calculation of the energy, exergy, energy and exergy efficiencies of the PV and PV/T systems. It is found that varies flow of energy (thermal and electrical) from a minimum of 312 W to maximum of 522 W, the PV exergy varies from a minimum of 18 W to a maximum of 41 W corresponding to the total energy of system and PV/T exergy varies from a maximum of 117 W to a minimum of 52 W, respectively. Meanwhile, the exergy efficiency for the PV/T system varies from a maximum of 18% to a minimum of 12% and exergy efficiency for the PV system varies from a minimum of 3% to a maximum 6%.

Downloads

Download data is not yet available.

References

Agrawal, S., Tiwari, G N. 2011. Performance Evaluation of Hybrid Modified Micro-channel Solar Cell Thermal Tile : an Experimental Validation. International Journal of Engineering, Science and Technology Vol.3 No.1, pp 244–254.

Coventry, S J. 2005. Performance of a Concentrating Photovoltaic/Thermal Solar Collector. Solar Energy 78: 211–222.

Dincer, I and Rosen, Marc, 2005. Thermodynamic Aspects of Renewables and Sustainable Development. Renewable and Sustainable Energy Reviews 9: 169–189.

Infield, D, Mei, L and Eicker, U. 2004. Thermal Performance Estimation of Ventilated PV Facades. Solar Energy,76(1-3): 93-98.

Ibrahim, A., Jin, G. Li., Daghigh, R., Saleh, M., Othman, M. Y., Ruslan, M. H., Sopian, K. 2009. Hybrid Photovoltaic Thermal (PV/T) Air and Water Based Solar Collectors Suitable for Building Integrated Applications. Am. J. Environ.Sci., 5(5) : 618 – 624.

Joshi, A S., Dincer, I. and Reddy, B.V. 2009. Thermodynamic Assessment of Photovoltaic Systems. Solar Energy, 83(8): 1139-1149.

Joshi, A J. and Tiwari, A. 2007. Energy and Exergy Analysis of a Hybrid Photovoltaic-Thermal (PV/T) Air Collector. Renewable Energy 322223 – 2241.

Joshi, A J., Dincer, I., Reddy, Bale V. 2011. Analysis of Energy and Exergy Efficiencies for Hybrid PV/T Systems. Int Journal of Low-Carbon Technologies, 6 : 64 – 69.

Sarhaddi, F., Farahat, S., Ajam, H., Behzadmehr, A. 2010. Exergetic Performance Evaluation of a Solar Photovoltaic (PV) Array. Australian Journal of Basic and Applied Sciences, 4(3) : 502-519, 2010.

Tripanagnostopoulos, Y N., Souliotis, T M., Yianoulis, P. 2002. Hybrid Photovoltaic/Thermal Solar System. Solar Energy 72 : 217 – 234.

Zondag, H A., de Vries, D W., van Helden, W G J., van Jolingen, R J C. 2003. The Yield of Different Combined PV-Thermal Collector Designs. Solar Energy 74: 253 – 269.