VALIDATION OF THE METHODS OF Hg DETERMINATION ON WASTE WATER TREATMENT PLANT SAMPLES USING COLD VAPOUR-ATOMIC ABSORPTION SPECTROPHOTOMETER (CV-AAS)TECHNIQUES

Authors

  • Rika anggraini Kimia FMIPA
  • Rita Hairani Jurusan Kimia Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Mulawarman
  • Aman Sentosa Panggabean Jurusan Kimia Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Mulawarman

DOI:

https://doi.org/10.30872/jkm.v16i1.667

Keywords:

Hg, validation methode, CV-AAS

Abstract

The research about validation of the method of Hg determination on the sample from wastewater treatment plant (WWTP) PT. Badak NGL Bontang, Kalimantan Timur using cold vapour-atomic absorption spectrophotometer (CV-AAS) techniques has been conducted. To obtain a valid measurement result, determinations of the important several parameters that influence the method validation are used. The results of research showed that 20% SnCl2 solution could be used as a reducing agent. The analytic performance of measurement obtain is good, showed with the linearity (r) value ≥ 0.995, LOD was 0.2530 ppb, LOQ was 0.8432 ppb, MDL was 0.6427 ppb and repeatability and reproducibility are shown as % RSD < 2/3 CV Horwitz values. The accuracy of this method is very good with a percentage of recovery value of 114.88%. Based on the results of this research, CV-AAS method can be used in the determination of Hg in WWTP samples with the valid results.

Downloads

Download data is not yet available.

References

[1]Palar. (1994). Pencemaran dan Toksikologi Logam Berat. Jakarta: Rineka Cipta.
[2]Budiono, A. (2003). Pengaruh Pencemaran Merkuri Terhadap Biota Air. Makalah pengantar Falsafah Sains Institut Pertanian Bogor.
[3]Riyanto. (2014). Validasi dan Verifikasi Metode Uji. Yogyakarta: Penerbit Deepublish.
[4]Taufiq, M., Sabarudin. A., dan Mulyasuryani, A. (2016). Pengembangan dan Validasi Metode Destruksi Gelombang Mikro untuk Penentuan Logam Berat Kadmium dan Timbal dalam Cokelat dengan Spektoskopi Serapan Atom (SSA), 2, pp. 31–37.
[5]Dean J. R. (1997). Atomic Absorption and Plasma Spectroscopy. Published on behalf of ACOL (Univercity of Greenwich), Chichester, England, Hal. 59.
[6]Panggabean, A. S, Pasaribu, S. P, and Kristiana, F. (2018). The Utilization of Nitrogen Gas a Carrier Gas in Determination of Hg Ions Using Cold Vapor-ATOMIC Absorption Spectrophotometer (CV-AAS). Indones. J. Chem. 18 (2). 279-285.
[7]Susanna, T. S. (2007). Unjuk Kerja Metode Uji Total Merkuri (Hg) Dalam Contoh Bahan Biologis Menggunakan CV-AAS. Yogyakarta: Pusat Teknologi Akselerator dan Proses Bahan.
[8]Dong, L., Yan, X., Li, Y., Jiang, Y., Wang, S., Jiang, D. (2004). On-Line Coupling Of Flow Injection Displacement Sorption Preconcentration to High-Performance Liquid Chromatography for Speciation Analysis Of Mercury in Seafood,J. of Chrom. A. 1036. 119-125.
[9]Silva M. F., Tóthi. V, and Rangel A. O. S. S . (2006). Determination of Mercury in Fish by Cold Vapour Atomic Absorption Spectrophotometry Using a Multicommuted Flow Injection Analysis System Vol . 22.Anal. Sci., The Japan Society for Analytical Chemistry.
[10]Arbab-Zavar, M., Mahmoud, H.,Chamsaz, G.H., and Masrournia, M. (2003). Determination of Mercury(II) Ion by Electrochemical Cold Vapor Generation Atomic Absorption Spectrometry, Anal. Sci. 19(5). 743-746
[11]Tomiyasu, T., Nagano, A., Sakamoto, H.,and Yonehara, N. (1996). Differential Determination of Organic Mercury and Inorganic Mercury in sediment, soil and aquatic organism by Cold Vapor Atomic Absorbtion Spectrometry.Anal. Sci. 12. 477-481.
[12]Zhu, S., Chen, B., He, M., Huang, T., and Hu, B. (2017). Speciation of mercury in water and fish samples by HPLC-ICP-MS after magnetic solid phase extraction, Talanta, 171. 213-219.
[13]Gao, Z., andMa, X. (2011). Speciation analysis of mercury in water samples using dispersive liquid–liquid microextraction combined with high-performance liquid Chromatography,Anal. Chim. Acta. 702(1). 50-55.
[14]Fithriani, A., Zulharmita., dan Dinda, R.F. (2013). Identifikasi dan Penetapan Kadar Merkuri Dalam Krim Pemutih Kosmetika Herbal Menggunakan Spektrofotometer Serapan Atom. Jurnal Sains dan Teknologi Farmasi. 18. 28-34.
[15]Harmita.(2004). Petunjuk Pelaksanaan Validasi, I(3), pp. 117–135.
[16]Panggabean, A. S., Pasaribu, S., Bohari and Nurhasanah. (2014). Preconcentration of Chromium (VI) at Trace Levels Using Acid Alumina Resin With Column Method, Indones. J. Chem. Sci., Vol. 14, no. 1, pp. 51–56
[17]Panggabean, A.S., Pasaribu, S.P., Amran, M.B., and Buchari. (2013). Gas-liquid separator integrated to HG-QFAAS method for determination of tin at trace levels in the water samples.Eurasian Journal of Analytical Chemistry. 8(1). pp. 17-27
[18]Harvey, D. (2000). Modern Analytical Chemistry. Amerika Serikat (US): Mc-Graw-Hill.
[19]Panggabean, A. S and Yusuf, B. (2015). Determination of Chromium (VI) By Using Chitosan-1,5-Diphenyl Carbazide Resin Modified at The Preconcentration System With Colomn Method. Int. J. Pharma and Bio Sci. pp. 101–111, 2015.

Downloads

Published

2018-11-29

Issue

Section

Artikel

Most read articles by the same author(s)

<< < 1 2