DECREASED LEVEL OF METAL IONS OF COPPER (CU) IN THE ELECTROPLATING INDUSTRY WASTE WATER USING ELECTRODEPOSITION METHOD

  • Tangke Veronika Jurusan Kimia, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Mulawarman
  • Bohari Yusuf Jurusan Kimia FMIPA Universitas Mulawarman
  • Rahmat Gunawan Jurusan Kimia FMIPA Universitas Mulawarman

Abstract

The reduction of copper concentration in the electroplating industry wastewater by electrodeposition method by means of Atomic Absorption Spectrophotometer (AAS). The result of research showed that degradation and is big of elimination percent of copper metal have with the effect of time contact and voltage at optimum hence in getting results of final concentration of iron (Fe) successive plate 4,02 ppm and 2,84 ppm of concentration early 35,86 ppm and elimination percent of exclusion at optimum parameter in getting result successive 88,403 % and 92,069 %. While the results of the final concentration of Aluminium (Al) successive plate 2,38 ppm dan 2,22 ppm of concentration early 35,86 ppm and elimination percent of exclusion at optimum parameter in getting result successive 93,363 % dan 93,814%.

Keyword
Electrodeposition, Electroplating industry wastewater, Copper (Cu), Iron (Fe), Alumunium (Al)

Downloads

Download data is not yet available.
Published
2018-11-29
How to Cite
VERONIKA, Tangke; YUSUF, Bohari; GUNAWAN, Rahmat. DECREASED LEVEL OF METAL IONS OF COPPER (CU) IN THE ELECTROPLATING INDUSTRY WASTE WATER USING ELECTRODEPOSITION METHOD. JURNAL KIMIA MULAWARMAN, [S.l.], v. 16, n. 1, p. 60-65, nov. 2018. ISSN 2476-9258. Available at: <http://jurnal.kimia.fmipa.unmul.ac.id/index.php/JKM/article/view/415>. Date accessed: 20 apr. 2024. doi: https://doi.org/10.30872/jkm.v16i1.415.
Section
Artikel

Most read articles by the same author(s)